Zelio Time
REXL, RE17 and RE22 type timer relays

Timing relays to master your time in all simplicity!
Features
- A complete range of timers designed to provide unmatched efficiency and accuracy.
- The innovative yet affordable Zelio Time - Near Field communication (NFC) marks a significant step in technological advancement for energy marketplace, expecting greater efficiency.
- Ergonomic and configurable range 17.5mm, 22.5mm Modular timer Relays RE17,RE22, Panel-mounted/plug-in timer 48x48mm format RE48, and plug-in miniature timer in 20x27mm format REXL
- Single or Multifunction available
- Wide power supply range from 24 to 240 V
- Single timing range or multi-range from 0.02s to 300 hrs
- Relay or Solid-state output
- Settings protection by IP 50 sealable plastic cover
- Conformity to IEC 61812-1, EN 61812-1 standards UL, CSA, GL, RCM, EAC, CCC, China ROHS
- A Simple approach to achieve higher efficiency
- Simple, fast, and easy to set up thanks to accurate adjustments and legible wiring diagrams on the side of Zelio Timer Relays
- A flexible and high performing solution thanks to a wide choice of outputs and either screw or spring connection terminals
- Zelio Timer Relays RE22 also has unique features:
- Innovative: Dial pointer LED indicator and "Diagnostic Button" to assist commissioning and trouble shooting
- Compact & reliable
- Energy efficient: simple to implement, to operate and maintain
- Compliant to standards & certifications
- QR code embedded to instruction sheet for easy setting
Applications
- Suitable for a wide range of applications:
- Machines : single machine, and industrial automation and processes
- Buildings : lighting control, access control door looks, roller shutters
- Water segment : pumping and irrigation systems
- HVAC : fans and centralized water
Index
1. Single function dial timers (REXL2, REXL4) click here to see the functions
(back to index)Rated current 5A, Timing range 0.1s - 100h, Function A | |||||||||
---|---|---|---|---|---|---|---|---|---|
12Vdc | 24Vdc | 24Vac | 120Vac | 230Vac | |||||
2 CO contacts DPDT |
|||||||||
4 CO contacts DPDT |
2. Multi function DIN rail timers (RE17) click here to see the functions
(back to index)Characteristics | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Ac | At | B | Bw | C | D | Di | H | Ht | |||
0.7 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ |
Characteristics | click here to see the functions | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
A | Ac | Act | At | B | C | Ct | D | Di | Dit | Diw | Dt | H | Ht | ||||
0.1s-100h | 24-240Vac | 2 CO contact | 5 | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | ⬤ | - | - | ⬤ | - | - | - | - | - | - | - | - | - | - | ||
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | ⬤ | - | - | - | ⬤ | - | - | - | - | - | - | - | - | - | ||
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | - | ⬤ | - | - | - | ⬤ | - | - | - | - | - | - | - | - | ||
0.1s-10h | 24Vdc/24-240Vac | 1 CO contact | 8 | ⬤ | - | - | ⬤ | ⬤ | ⬤ | - | ⬤ | ⬤ | - | - | - | ⬤ | ⬤ | ||
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | - | ⬤ | ⬤ | - | - | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | - | - |
Characteristics | click here to see the functions | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Ac | C | H | Ht | L | Li | |||
0.1s-100h | 24Vdc/24-240Vac | 1 solid state output | 0.7 | - | ⬤ | - | - | - | - | |
0.1s-100h | 24Vdc/24-240Vac | 1 solid state output | 0.7 | - | - | - | - | ⬤ | ⬤ | |
0.1s-100h | 24Vdc/24-240Vac | 1 solid state utput | 0.7 | - | - | ⬤ | - | - | - | |
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | - | - | ⬤ | ⬤ | - | - | |
0.1s-100h | 24Vdc/24-240Vac | 1 CO contact | 8 | - | - | - | - | ⬤ | ⬤ | |
0.1s-100h | 12Vac | 1 CO contact | 8 | - | - | - | - | ⬤ | ⬤ |
3. Multi function DIN rail timers (RE22) click here to see the functions
(back to index)Characteristics | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Ac | At | B | Bw | C | D | Di | H | Ht | |||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ |
Characteristics | click here to see the functions | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
A | Ac | Act | At | Aw | C | Ct | D | Di | Dit | Diw | Dt | Dw | H | Ht | Hw | Qg | Wt | Qgt | Qt | Qtt | W | |||
8 | ⬤ | - | - | - | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||
8 | ⬤ | - | - | ⬤ | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||
8 | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | - | - | - | - | ⬤ | ⬤ | ||||
8 | ⬤ | - | - | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||
8 | ⬤ | - | - | - | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||
8 | ⬤ | - | - | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ||||
8 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ⬤ | ⬤ |
Characteristics | click here to see the functions | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Ac | Ad | Ah | Ak | Akt | At | N | O | P | Pt | Tl | Tt | W | |||
8 | ⬤ | - | - | - | - | ⬤ | - | - | - | - | - | - | - | ||||
8 | - | - | - | ⬤ | ⬤ | - | - | - | - | - | - | - | - | ||||
8 | ⬤ | - | - | - | - | - | - | - | - | - | - | - | - | ||||
8 | - | ⬤ | ⬤ | - | - | - | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ | ⬤ |
Characteristics | click here to see the functions | |||||||
---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
C | Ct | D | Dw | |||
8 | ⬤ | ⬤ | - | - | ||||
8 | - | - | ⬤ | ⬤ | ||||
8 | ⬤ | - | - | - | ||||
8 | - | - | ⬤ | ⬤ |
Characteristics | click here to see the functions | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
H | He | Hw | K | L | Li | Lit | Lt | |||
8 | ⬤ | - | ⬤ | - | - | - | - | - | ||||
8 | ⬤ | - | ⬤ | - | - | - | - | - | ||||
5 | - | - | - | ⬤ | - | - | - | - | ||||
5 | - | - | - | ⬤ | - | - | - | - | ||||
5 | - | ⬤ | - | ⬤ | - | - | - | - | ||||
8 | - | - | - | - | ⬤ | ⬤ | ⬤ | ⬤ |
Characteristics | click here to see the functions | ||||||||
---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Q | Qc | Qe | Qg | Qt | |||
8 | ⬤ | - | - | - | - | ||||
8 | ⬤ | - | - | - | - | ||||
8 | - | ⬤ | - | - | - | ||||
8 | - | - | ⬤ | - | - | ||||
8 | - | - | ⬤ | - | - | ||||
8 | - | - | - | ⬤ | - | ||||
8 | - | - | - | - | ⬤ |
4. Multi function plug-in timers (RE48) click here to see the functions
(back to index)Characteristics | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product |
Current (A) |
Pin relay | A | A1 | A2 | B | C | Di | H1 | H2 | L | Li |
Screw connector |
Soldering pin | Protective cover | |||||||
Front terminal | Rear terminal | |||||||||||||||||||||
5 | 8-pin | ⬤ | - | - | - | - | - | - | - | - | - | |||||||||||
5 | 8-pin | - | ⬤ | ⬤ | - | - | - | ⬤ | ⬤ | - | - | |||||||||||
5 | ⬤ | - | - | ⬤ | ⬤ | ⬤ | - | - | - | - | ||||||||||||
5 | - | - | - | - | - | - | - | - | ⬤ | ⬤ |
5. Multi function dial timers (RENF22) click here to see the functions
Functions A, Ac, Ad, Ak, Ah, At, B, Bw, C, D, Di, Dit, Dt, H, Ht, L, Li, Lit, Lt, N, O, P, Pt, Qt, Qtt, Tl, Tt, W
(back to index)24-240Vac/Vdc | ||
2 CO contacts DPDT |
6. Summary of timing functions
(back to index)



R: Relay or solid state output
R1/R2: 2 timed outputs
R2 inst.: Second output is instantaneous if the correct position is selected
T: Timing period
X1/X2/Y1: Control contacts
Ta: Adjustable on-delay
R1/R2: 2 timed outputs
R2 inst.: Second output is instantaneous if the correct position is selected
T: Timing period
X1/X2/Y1: Control contacts
Ta: Adjustable on-delay
Timer functions table
Function | A | Ac | Act | Ad | Ah | Ak | Akt | At | Aw | B | Bw | C | Ct | D | Di | Dit | Diw | Dt | Dw | H | He | Ht | Hw | K | L | Li | Lit | Lt | N | O | P | Pt | Q | Qc | Qe | Qg | Qgt | Qt | Qtt | Tl | Tt | W | Wt |
Description | Power ON-delay relay | ON-delay and OFF-delay relay with control signal | ON-delay and OFF-delay relay with control signal and pause/summation control signal | Pulse delayed relay with control signal | Pulse delayed relay (single cycle) with control signal | Asymmetrical ON-delay and OFF-delay relay with control signal | Asymmetrical ON-delay and OFF-delay relay with control signal and pause/summation control signal | Power ON-delay relay with pause/summation control signal | Power ON-delay relay with retrigger/restart control signal | Single interval relay with control signal | Double interval relay with control signal | OFF-delay relay with control signal | OFF-delay relay with control signal and pause/summation control signal | Symmetrical fashing relay (starting pulse-OFF) | Symmetrical fashing relay (starting pulse-ON) | Symmetrical fashing relay (starting pulse-ON) with pause/summation control signal | Symmetrical fashing relay (starting pulse-ON) with retrigger/restart control signal | Symmetrical fashing relay (starting pulse-OFF) with pause/summation control signal | Symmetrical fashing relay (starting pulse-OFF) with retrigger/restart control signal | Interval relay | Pulse-ON de-energization | Interval relay with pause/summation control signal | Ineterval relay with retrigger/restart control signal | Delay on de-energization (without auxiliary supply) | Asymmetrical flashing relay (starting pulse-OFF) | Asymmetrical fashing relay (starting pulse-ON) | Asymmetrical fashing relay (starting pulse-ON) with pause/summation control signal | Asymmetrical fashing relay (starting pulse-OFF) with pause/summation control signal | Safe-guard relay | Delayed Safe-guard relay | Pulse delayed relay with fxed pulse length | Pulse delayed relay with fxed pulse length and pause/summation control signal | Star-delta relay (2 NO outputs with same common) | Star-delta relay (1 CO output) | Star-delta relay (1 NC + 1 NO outputs with split common) | Star-delta relay (2 CO outputs with same common) | Star-delta relay (2 CO outputs with same common) with pause/summation control signal | Star-delta relay (2 CO outputs with split common) | Star-delta relay (2 CO outputs with split common) with pause/summation control signal | Bistable relay with control signal on | Retriggerable bistable relay with control signal on | Interval relay with control signal OFF | Interval relay with control signal OFF and pause/summation control signal |
Time graph | (1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() ![]() (1 output) ![]() ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() ![]() (1 output) ![]() ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() |
(1 output)
![]() ![]() (1 output) ![]() ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
(1 output)
![]() (1 output) ![]() |
Remarks | Except for RE17⬤, RE22R2AMU,RE22R2MMW, RE22R2MMU, and RE22R2MJU, timing can be interrupted / paused each time Y1 closes. When the cumulative total time elapsed reaches the preset value T, the output(s) R close(s). | Function D with Y1 is only for the RE17 range and RE22R2MJU, RE22R2MMU, and RE22R2MMW references. | For RE17⬤, RE22R2MMW, RE22R2MMU, and RE22R2MJU, timing can be interrupted/paused each time Y1 closes. | Function L with Y1 is only for the RE17 range. |